Part Number Hot Search : 
95160 2PTBG B357D DG442DYT TMS470 CM600D ES5VL 2PTBG
Product Description
Full Text Search
 

To Download NTQ123 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  technical support: (888) 41-astec or (407) 241-2752 americas: (760) 930-4600 europe (uk) 44 (1384) 842-211 asia (hk) 852-2437-9662 rev 10.19.04 106 special features electrical specs 70-120 watts NTQ123 series ? active power factor correction ? en61000-3-2 compliance ? remote sense on outputs one and two ? power fail and remote inhibit ? single wire current sharing on outputs one and two ? adjustable main outputs ? built-in class b emi filter ? overvoltage protection ? overload protection ? thermal overload protection operating temperature: 0 to 50c ambient; derate each output at 2.5% per degree from 50 to 70c electromagnetic susceptibility: designed to meet en61000-4, -2, -3, -4, -5, -6, -8, -11 level 3 humidity: operating; non-condensing 5% to 95% vibration: three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 g peak 5 hz to 500 hz, operational storage temperature: -40 to 85c temperature coefficient: .04% per c mtbf demonstrated: >1 million hours at full load and 25c ambient conditions input input range 85-264 vac frequency 47-63 hz inrush current 38 a max., cold start @ 25c efficiency 65% typical at full load emi filter fcc class b conducted and radiated, cispr 22 class b conducted and radiated, en55022 class b conducted and radiated, vde 0878 pt3 class b conducted and radiated. power factor 0.99 typical safety ground leakage current <1 ma @ 50/60 hz, 264 vac input output maximum power 70 w convection, 120 w with 30 cfm forced air adjustment range 5% minimum on outputs one and two hold-up time 20 ms @ 120 w load, 120 vac input overload protection short circuit protection on all outputs. case overload protected @ 110-145% above peak rating overvoltage protection 3.3 v and 5 v output: 20% to 35% above nominal output logic control power failure ttl logic signal goes high 100-500 msec after 5 v output; it goes low at least 4 msec before loss of regulation remote inhibit requires an external ttl signal to inhibit outputs remote sense compensates for 0.5 v lead drop minimum, will operate without remote sense connected. reverse connection protection. environmental safety vde 0805/en60950 (iec950) 21310-3336-0004 ul ul1950 e186249 csa csa 22.2-234 level 3 lr109492c nemko en 60950/emko-tue p98100870 (74-sec) 203 babt en60950/en41003 608497 cb certificate and report 5009 ce mark (lvd) total power: 70-120 watts input voltage: 85-264 vac # of outputs: quad
europe astec house, waterfront business park merry hill, dudley west midlands, dy5 1lx, uk telephone: 44 (1384) 842-211 facsimile: 44 (1384) 843-355 americas 5810 van allen way carlsbad, ca 92008 telephone: 760-930-4600 facsimile: 760-930-0698 107 www.astecpower.com ordering information asia units 2111-2116, level 21 tower1, metroplaza 223, hing fong road kwai fong, new territories hong kong telephone: 852-2437-9662 facsimile: 852-2402-4426 model output minimum maximum load with maximum load with peak regulation 2 ripple number voltage load 4 convection cooling 30 cfm forced air load 1 p/p (pard) 3 NTQ123 +3.3 v 0 a 14 a 25 a 28 a 2% 50 mv +5 v 2 a 12.5 a 24 a 28 a 2% 50 mv +12 v 0 a 1 a 2 a 4 a 3% 120 mv -12 v 0 a 0.5 a 1 a 1.5 a 3% 120 mv 1. peak current lasting <30 seconds with a maximum 10% duty cycle. 2. at 25c including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. peak-to-peak with 20 mhz bandwidth and 10 f in parallel with a 0.1 f capacitor at rated line voltage and load ranges. 4. minimum loads are required. in parallel minimum loads are 2.5 a on the 5 v output and 1 a on the 3.3 v output for each power supply. connector sk1 pin 1 ground pin 3 neutral pin 5 live sk5 pin 1 +12 v pin 2 common pin 3 -12 v sk6 pin 1 3.3 v swp pin 2 -3.3 v sense pin 3 +3.3 v + sense pin 4 5 v swp pin 5 common pin 6 +5 v sense pin 7 -5 v sense pin 8 + inhibit pin 9 - inhibit pin 10 power fail mating connectors ( sk1) ac input: molex: 09-50-8051 (usa) molex: 09-91-0500 (uk) pins: 08-58-0111 sk2,3,4: molex series 19141-0058/0063 (sk5) 12v molex:09-50-8031 (usa) molex: 09-91-0300 (uk) pins: 08-58-0111 ( sk6) control signals: molex: 90142-0010 pins: 90119-2110 or amp: 87977-3 pins: 87309-8 astec connector kit #70-841-012 notes: 1. specifications subject to change without notice. 2. all dimensions in inches (mm), tolerance .02. 3. remote inhibit requires an external 5 v @ 10 ma to activate 4. mounting maximum insertion depth is 0.12. 5. warranty: 1 year 6. weight: 1.38 lb. / .63 kg pin assignments NTQ123 series


▲Up To Search▲   

 
Price & Availability of NTQ123

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X